Warehouse floor plan
Draw your warehouse. Get the layout and the parts list.
Enter the inside dimensions, columns, dock doors and offices. The planner lays out selective pallet racking, counts the pallet positions and lists the parts from our catalogue, with an estimated total.
Indicative plan: the final layout, capacities and compliance (sprinklers, CNESST, manufacturer) are validated by AREIC and, when needed, an engineer.
Drag to move the plan once zoomed in; mouse wheel or buttons to zoom.
120 × 200 ft: 18 rack rows, 207 bays, ≈ 2,070 pallet positions.
- Racking
- Aisles
- Dock staging
- Office
- No rack
- Walkway
- Tunnel
- Column
- Dock door
- Emergency door
1. Building
Under the lowest obstruction: joists, sprinklers, lights.
Existing plan (optional)
Upload a PNG, JPG or PDF plan (10 MB max.) to trace over it. It stays in your browser: nothing is sent.
2. Obstacles
3. Forklift and pallets
to confirm with AREIC
to confirm with AREIC
Face width × depth into the rack.
Passed on to AREIC, who validates the parts’ capacity.
Row orientation
Advanced assumptions
to confirm with AREIC
Result
96 in bays (2 pallets) · 42 in frames · 60 in per level · north–south rows
Pallet positions
≈ 2,070
Bays
207
Levels
5
under the clear height minus the clearance
Floor utilisation
28.7 %
Frames (uprights)
225
Beam pairs
828
Safety bars
3,312
Bays with anti-fall panels
17
Protectors
62
Row spacers
96
Rows
18
Parts list (AREIC catalogue)
Working out the parts list…
Some parts are on request: firm price by quote
Material only, before installation, delivery and taxes
—
Next steps
The plan is kept in the link and in this browser.
Assumptions
- Building: 120 × 200 ft (24,000 sq ft), 30 ft clear height
- Sprinkler clearance: 36 in; wall gap: 8 in
- Forklift: Counterbalance forklift; 12 ft aisles; 20 ft max lift (to confirm with AREIC)
- 40 × 48 in pallets, 2,000 lb, 48 in load height
- 96 in bays (2 pallets), 42 in frames, 60 in per level, the floor counts as a level
- Without wire decks: 2 safety bars per pallet position
- Back-to-back double rows (8 in spacers between the frames) and single rows along the walls; a cross-aisle at both ends
- Rows along the walls may start against the end wall (8 in), with no guard or taller upright on that end
- Single row in the middle, reachable from both sides (17 bays): anti-fall mesh panels on its back, 4 in off the uprights, from the first level to the top, and full-height uprights (panels to confirm with AREIC, not in the total)
- columns every 40 × 40 ft (12 in); 3 dock doors, 40 ft dock staging; 1 excluded zone
- Protectors: an end-of-aisle guard (required) at each row end and a protector (recommended) on the aisle-side upright of each end frame; 2 spacers per frame pair
- Capacity certification (warehouse layout and engineer’s stamp) required: cost depends on the project, confirmed by AREIC